top of page

CSB: One Shot Plug-In Timer

csb.jpg

• Digital CMOS Design

 

• 10 Amp, DPDT

 

• ±0.2% Repeatability

 

• Transient Protected

 

• Timing Ranges Up to 

  24 Hours

Operation

One Shot

When input voltage is available, closure of the customer supplied contact (C1) will energize the internal relay and begin the timing cycle. At the end of the timed period, the relay will be de-energized. Closure of the contact (C1) may be maintained, momentary or repeated. The relay will only remain energized for the time period initiated by the initial closure of the contact. The CSB resets when timed cycle is complete with the contact open or the input voltage is removed.

 

Specifications

Electrical

Input Voltage:

     24 or 115VAC, ±10%, 50/60Hz

     24 or 110VDC ±10%,

     Filtered to Full Wave.

Time Delays:

     Type: Adjustable or Factory Fixed

     Range: 50 Milliseconds to 24 Hours

     Repeat Accuracy: ±0.2% of Time Range or

           Â±10Milliseconds, Whichever is Greater

     Fixed Time Accuracy: ±5% Worst Case

Control Contact Response Times:

     Start Timing: 50 Milliseconds, Typical

     After Timing: 50 Milliseconds, Typical

Protection: Varistor and/or R-C Network

Power Consumption: 5VA

Output Relay:

     10 Amps @ 120/240VAC

     500,000 Full Load Electrical Cycles

     50,000,000 Mechanical Cycles

U.L. Ratings:

     6.5 Amps, 1/3 HP, 125VA @ 240VAC

     7 Amps, 1/6 HP, 125VA @ 120VAC

 

Physical

Mounting: Plug-In

Termination: 8 or 11 Pin & Blade Base

Packaging: Dust Cover

Weight: 7 Oz.

 

Ambient Temperatures

Operating: -10°C to 65°C

U.L. Operating: -10°C to 40°C

Storage: -10°C to 85°C

 

bottom of page